Instruments: Detailed View

Chicago Campus

  • BD FACSymphony S6 Cell Sorter

    Cell Sorter

    Features:

    The BD FACSymphony S6 instrument offers six-way sorting and supports analysis of up to 30 parameters. This advanced platform features an ultra-quiet electronics system adapted from the defense industry that improves detection sensitivity to enable the sorting of rare cell types. Excitation lines are at 488nm, 355nm, 405nm, 552nm and 640nm wavelengths.

  • BD FacsAria SORP 6-Laser (Instrument #1)

    Features:

    The BD FACSAria SORP 5-laser is a high speed multilaser droplet cell sorter. This system is fitted with five lasers – excitation lines are 355nm, 405nm, 488nm, 561nm, 640nm and 750nm and can collect up to 17 parameters including forward and side scatter. The Aria has four-way and single-cell sorting capabilities and is equipped with ACDU allowing for slide and plate (6, 24, 48, 96 and 384 wells) sorting.

    This instrument is housed in a BioProtect IV-LE-Bio Containment Hood; thus allowing for sorting of potentially bio-hazardous samples and a broader range of live unfixed human cells.

     

  • BD FacsAria SORP 5-Laser (Instrument #2)

    Features:

    The BD FACSAria SORP 5-laser is a high speed multilaser droplet cell sorter. This system is fitted with five lasers – excitation lines are 355nm, 405nm, 488nm, 561nm and 640nm and can collect up to 17 parameters including forward and side scatter. The Aria has four-way and single-cell sorting capabilities and is equipped with ACDU allowing for slide and plate (6, 24, 48, 96 and 384 wells) sorting.

    This instrument is housed in a separate negative pressure lab space within a BioProtect IV-LE-Bio Containment Hood; thus allowing for sorting of potentially bio-hazardous samples and a broader range of live unfixed human cells.

     

  • BD FacsAria SORP 5-Laser (Instrument #3)

    Features:

    The BD FACSAria SORP 5-laser is a high speed multilaser droplet cell sorter. This system is fitted with four lasers – excitation lines are 355nm, 405nm, 488nm, 560nm and 640nm and can collect up to 16 parameters including forward and side scatter. The Aria has four-way and single-cell sorting capabilities and is equipped with ACDU allowing for slide and plate (6, 24, 48, 96 and 384 wells) sorting.

  • BD FacsMelody SORP 3-Laser

    Cell Sorter

     

    Features:

    With new automation taking care of all the sort stream setup and monitoring, the new BD FACSMelody cell sorter makes running a sorter as easy as running an analyzer. User friendly BD FACSChorus™ software provides researchers a supportive and comprehensive workflow experience. This system is fitted with three lasers – excitation lines are 405nm, 488nm, and 561nm laser . The instrument can collect up to 11 parameters including forward and side scatter. Due to the wide range of excitation wavelengths, many available fluorescent probes utilized in flow cytometry can be accommodated. The sorter has two-way and single-cell sorting capabilities and is equipped with ACDU allowing for plate sorting (96 wells).

    This instrument is housed in a BioProtect IV-LE-Bio Containment Hood; thus allowing for sorting of potentially bio-hazardous samples and a broader range of live unfixed human cells.

     

  • BD FacsAria IIu 3-Laser (Instrument #4)

    Features:

    The BD FACSAria IIu 3-laser is a high speed multilaser droplet cell sorter. This system is fitted with three lasers – excitation lines are 405nm, 488nm and 640nm and can collect up to 11 parameters including forward and side scatter. The Aria has four-way and single-cell sorting capabilities and is equipped with ACDU allowing for slide and plate (6, 24, 48, 96 and 384 wells) sorting.

     

  • BD FACSymphony A5.2 Spectral Analyzer

    Analyzer

    Features:

    The Symphony A5 Spectral is a 50 parameter capable bench-top multilaser spectral flow cytometer equipped with five lasers.  Excitation lines are at 488nm, 355nm, 405nm, 552nm and 640nm wavelengths.

     

     

  • BD FACSymphony A5 Cell Analyzer

    Analyzer

    Features:

    The Symphony A5 is a 28 color capable bench-top multilaser flow cytometer equipped with five lasers.  Excitation lines are at 488nm, 355nm, 405nm, 552nm and 640nm wavelengths.

     

     

  • BD LSRFortessa 6-Laser

    Features:

    The Fortessa is a 16 color capable bench-top multilaser flow cytometer equipped with six lasers.  Excitation lines are at 488nm, 355nm, 403nm, 552nm, 640nm and 690nm wavelengths.  It is also equipped with a High Throughput Sampler (HTS) which allows for sample loading from a 96 or 384 well microtiter plate for screening assays.

     

  • Apogee Micro-Plus Flow Cytometer

    Analyzer

     

    Features:

    The new Micro-PLUS is capable of measuring particles which scatter 1000 times less than 200nm latex beads,tuned for extreme small particle applications: extracellular vesicles, virus applications (flow virometry), protein aggregation, bacteria, nanoparticles. The amount of scattered light falls rapidly with particle size so this exceptional performance is required for extreme small particle applications and opens up new areas of research. The instrument will house 3 spatially separated lasers, 12 optical detectors including novel noise reduction algorithm implemented in an Altera™ FPGA

     

     

  • Cellometer K2 Fluorescent Viability Cell Counter

    Features:

    The Cellometer K2 utilizes bright field imaging and dual-fluorescence imaging to quickly and accurately identify and count individual cells, including primary cells from peripheral blood, cord blood, bone marrow, and other complex samples for use in a wide range of research areas. Dual-color fluorescence allows for staining of live and dead nucleated cells, generating accurate viability results even in the presence of debris, platelets, and red blood cells. Cell count, concentration, diameter, and % viability are automatically calculated and reported. Cellometer K2 Image Cytometer has the ability to perform basic cell-based assays such as cell cycle, apoptosis, and green fluorescent protein (GFP) population analysis.

  • Multiple Offline Analysis Workkstations

Evanston Campus

  • BD FacsAria IIu 4-Laser (Instrument #5)

    Features:

    The AriaII is a high speed multilaser droplet cell sorter. This system is fitted with three lasers – excitation lines are 355nm, 488nm, 560nm and 640nm. The Aria II has four-way and single-cell sorting capabilities and is equipped with ACDU allowing for slide and plate (6, 24, 48, 96 and 384 wells) sorting.

     

  • BD LSRFortessa 6-Laser

    Features:

    The Fortessa is a 16 color capable bench-top multilaser flow cytometer equipped with six lasers.  Excitation lines are at 488nm, 355nm, 403nm, 552nm, 640nm and 690nm wavelengths.  It is also equipped with a High Throughput Sampler (HTS) which allows for sample loading from a 96 or 384 well microtiter plate for screening assays.

     

  • Offline Analysis Worstation